Chromeleon 6.8 - Specifications

Architecture

Distributed client/server: "server" software module manages all real-time instrument control and data acquisition tasks; "client" software module provides all user interface functions. Any number of client instances can connect to any number of server instances. Client and server modules can be used together on the same PC (a "workstation"), or on separate PCs ("instrument controllers" and "remote clients").

Operating Systems

Microsoft® Windows® XP, Vista or Windows 2000 (can be mixed in network installations).

Relational Database

  • Fast retrieval of samples based on any combination of sample, sequence, and result criteria.
  • Compatible with Oracle® 8i, 9i, 10g, Microsoft SQL Server 7, Microsoft SQL Server 2000, Microsoft SQL Server 2005, and Microsoft Jet Engine 3/4 (Access MDB format).

Sample Management

Fast, easy generation of sequences using Sequence Wizard or LIMS Worklist import. Unlimited number of samples per sequence; unlimited number of sequences per batch.

Instrument Control

  • Up to six timebases (independent instrument systems) per workstation or instrument controller.
  • Up to two diode-array detectors per workstation.
  • Full control for over 300 different instruments from more than 30 manufacturers through RS-232, IEEE-488, DX-LAN, USB, LAN, etc. Programmable triggers for conditional execution of instrument control commands.

Data Acquisition

  • Direct digital data acquisition from most Dionex detectors; acquisition from other instruments via UCI Universal Chromatography Interfaces at rates up to 100 Hz with 25-bit dynamic resolution.
  • Up to 16 standard detector channels per time base (chromatography system), more for photodiode array and mass spectrometry channels.
  • Chromatogram run-times up to 999.999 min.

Peak Detection and Identification

  • More than 25 time-programmable detection options.
  • Easy manual manipulation of baselines.
  • Component identification based on absolute or relative retention time, with or without spectral matching.
  • Up to 1024 sample components per method.
  • Independently selectable identification parameters for each component.
  • Unlimited number of component groups per method.

Quantitation

  • External standard, internal standard, and internal/external standard methodologies.
  • Five sequence calibration mode options (fixed, total, additional, group, and bracketed).
  • Linear, quadratic, cubic, point-to-point, and exponential calibration curves.
  • 1/x, 1/x², 1/y, 1/y² polynomial curve weightings.
  • Choice of origin treatment (force, include, ignore).
  • Quantitation of identified and unidentified components using fixed or relative response factors.
  • Standard Addition methodology support.
  • Option to invert variables before curve fitting.
  • Blank and Matrix Blank correction options.
  • Independently selectable calibration options for each component.
  • Manual enable/disable of individual calibration points.
  • Instant updating of all results in response to any change (can be disabled).

Reporting

  • Integrated Microsoft Excel-compatible spreadsheet provides complete reporting flexibility with dynamic updating.
  • Extensive set of report variable and report table options facilitates generation of single-injection, calibration, summary, system suitability, audit trail, fraction collection, and other types of reports.
  • User-defined sample and peak variables are fully supported.
  • Optional Report Publisher allows incorporation of charts and user-defined formulas written in Excel syntax.

Optional Software Components

  • PDA Control supports collection of full-spectrum UV data from up to 2 photodiode-array detectors per workstation. (Peak purity analysis, spectral library matching, and method optimization tools can be used on any client station that has access to the acquired PDA data).
  • Mass Spectrometer Support for Finnigan AQA and Finnigan MSQ (Thermo Electron Corp.) provides full instrument control in ESI and APCI modes with positive and/or negative ionization; supports full-scan and multiple SIM channels; generates extracted ion chromatograms (post-run or real-time) and TICs; and provides interlinked, interactive displays of mass spectra and chromatograms from multiple channels. Supports advanced applications like mass-directed fraction collection.
  • Multiple Network Control permits instruments attached to a workstation or instrument controller to be accessed and controlled through remote clients, and provides network failure protection.
  • Report Publisher supports custom equations and charting.
  • GLP Option provides user access control, electronic signature, and modification history features.
  • Virtual Column Separation Simulator models gradient and isocratic IC separations and quickly finds optimum conditions for various IC applications.

Security

Security can be implemented at 3 levels: operating system, database, and application. At the application level, over 100 chromatography-specific privileges can be separately controlled for an unlimited number of Privilege Groups. Access to individual instruments, data sources, and data folders can be controlled for an unlimited number of Access Groups. Numerous administrator tools are provided. (GLP Option required).

Validation

  • Certificate of Software Validation provided with software media.
  • AutoQ — a full complement of automated validation tools including Software IQ, Software OQ, Instrument OQ, and Instrument PQ.

Audit Trails

  • Secure, computer-generated, time-stamped audit trails automatically record details of system usage:
  • Instrument Event Logs document all instrument and operator actions related to data acquisition.
  • Modification Histories document all changes made to control programs, methods, data objects, etc. (GLP Option required).
  • User Database Histories document user logins, login failures, password changes, privilege changes, and electronic signature events. (GLP Option required).

Electronic Signatures

Complete, seamless implementation of electronic signatures, compliant with requirements of 21 CFR Part 11 (GLP Option required).

Software Interfacing Capabilities

  • Import of ASCII sample worklists.
  • Direct import of raw data from Dionex PeakNet®, Agilent ChemStation, Agilent LAS and ANDI formats.
  • Export of results as text, native Microsoft Excel, and Portable Document Format (PDF) files.
  • Export of raw data in ANDI format (Types 1 and 2) and ASCII lists.
  • Direct interfacing to third-party applications through COM model using optional Software Developer's Kit. Fileless interfacing to LIMS using Labtronics LimsLinkCDS.